Model NO.: MV-90
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC
Model: Mv-90
Brand: Boan
Manufacture Standard: Icea S-93-639/NEMA Wc71/UL 1072
Rated Voltage: 25 Kv
Number of Cores: 3
Section: 1 AWG-750 Mcm
Class of Conductor: B
Type of Shield: Copper Tape
Trademark: DingAn
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544601200
Model NO.: MV-90
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC
Model: Mv-90
Brand: Boan
Manufacture Standard: Icea S-93-639/NEMA Wc71/UL 1072
Rated Voltage: 25 Kv
Number of Cores: 3
Section: 1 AWG-750 Mcm
Class of Conductor: B
Type of Shield: Copper Tape
Trademark: DingAn
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544601200
MV-90, Copper Tape Shield Power Cable, 25 KV, 3/C, CU/XLPE/CTS/PVC (ICEA S-93-639/NEMA WC71/UL 1072)
FeaturesUL Listed as MV-90. Rated as Sunlight Resistance for CT use, 1/0 AWG and larger. Oil Resistance I jacket. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.
ApplicationPrimary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.
StandardsUL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV - 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV- 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV - 46 kV.
SpecificationsMaximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures:
Wet and dry locations: Normal: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C
Engineering Information1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset crosslinked polyethylene (XLPE).
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap.
6. Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
7. Jacket: Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.
100% Insulation Levels (260 mil) |
133% Insulation Levels (320 mil) |
Size |
Number of Strands |
Conductor Nominal |
Jacket Thickness |
Approximate Outside Diameter |
Approximate Net Weight |
Jacket Thickness |
Approximate Outside Diameter |
Approximate Net Weight |
Copper |
Aluminum |
Copper |
Aluminum |
AWG of kcmil |
|
in |
mil |
in |
lb/kft |
mil |
in |
lb/kft |
1 |
19 |
0.3 |
110 |
2.33 |
2766 |
2210 |
- |
- |
- |
- |
1/0 |
19 |
0.34 |
110 |
2.41 |
3073 |
2372 |
110 |
2.73 |
3594 |
2892 |
2/0 |
19 |
0.38 |
110 |
2.5 |
3474 |
2590 |
140 |
2.88 |
4189 |
3306 |
3/0 |
19 |
0.42 |
110 |
2.65 |
4026 |
2911 |
140 |
2.98 |
4674 |
3559 |
4/0 |
19 |
0.48 |
140 |
2.83 |
4769 |
3365 |
140 |
3.10 |
5263 |
3859 |
250 |
37 |
0.52 |
140 |
2.95 |
5303 |
3642 |
140 |
3.22 |
5815 |
4153 |
300 |
37 |
0.57 |
140 |
3.06 |
5965 |
3974 |
140 |
3.33 |
6492 |
4500 |
350 |
37 |
0.62 |
140 |
3.16 |
6588 |
4262 |
140 |
3.42 |
7129 |
4803 |
400 |
37 |
0.66 |
140 |
3.25 |
7196 |
4541 |
140 |
3.52 |
7751 |
5095 |
500 |
37 |
0.74 |
140 |
3.41 |
8438 |
5118 |
140 |
3.68 |
9017 |
5696 |
600 |
61 |
0.81 |
140 |
3.6 |
9617 |
5630 |
140 |
3.94 |
10405 |
6418 |
750 |
61 |
0.91 |
140 |
3.88 |
11577 |
6600 |
140 |
4.15 |
12224 |
7246 |
MV-90, Copper Tape Shield Power Cable, 25 KV, 3/C, CU/XLPE/CTS/PVC (ICEA S-93-639/NEMA WC71/UL 1072)
FeaturesUL Listed as MV-90. Rated as Sunlight Resistance for CT use, 1/0 AWG and larger. Oil Resistance I jacket. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.
ApplicationPrimary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.
StandardsUL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV - 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV- 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV - 46 kV.
SpecificationsMaximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures:
Wet and dry locations: Normal: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C
Engineering Information1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset crosslinked polyethylene (XLPE).
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap.
6. Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
7. Jacket: Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.
100% Insulation Levels (260 mil) |
133% Insulation Levels (320 mil) |
Size |
Number of Strands |
Conductor Nominal |
Jacket Thickness |
Approximate Outside Diameter |
Approximate Net Weight |
Jacket Thickness |
Approximate Outside Diameter |
Approximate Net Weight |
Copper |
Aluminum |
Copper |
Aluminum |
AWG of kcmil |
|
in |
mil |
in |
lb/kft |
mil |
in |
lb/kft |
1 |
19 |
0.3 |
110 |
2.33 |
2766 |
2210 |
- |
- |
- |
- |
1/0 |
19 |
0.34 |
110 |
2.41 |
3073 |
2372 |
110 |
2.73 |
3594 |
2892 |
2/0 |
19 |
0.38 |
110 |
2.5 |
3474 |
2590 |
140 |
2.88 |
4189 |
3306 |
3/0 |
19 |
0.42 |
110 |
2.65 |
4026 |
2911 |
140 |
2.98 |
4674 |
3559 |
4/0 |
19 |
0.48 |
140 |
2.83 |
4769 |
3365 |
140 |
3.10 |
5263 |
3859 |
250 |
37 |
0.52 |
140 |
2.95 |
5303 |
3642 |
140 |
3.22 |
5815 |
4153 |
300 |
37 |
0.57 |
140 |
3.06 |
5965 |
3974 |
140 |
3.33 |
6492 |
4500 |
350 |
37 |
0.62 |
140 |
3.16 |
6588 |
4262 |
140 |
3.42 |
7129 |
4803 |
400 |
37 |
0.66 |
140 |
3.25 |
7196 |
4541 |
140 |
3.52 |
7751 |
5095 |
500 |
37 |
0.74 |
140 |
3.41 |
8438 |
5118 |
140 |
3.68 |
9017 |
5696 |
600 |
61 |
0.81 |
140 |
3.6 |
9617 |
5630 |
140 |
3.94 |
10405 |
6418 |
750 |
61 |
0.91 |
140 |
3.88 |
11577 |
6600 |
140 |
4.15 |
12224 |
7246 |
Brushless DC Motor
Brushless Motor
Biotept Brushless DC motors have various advantages such as high efficiency, potential to downsize, ability to run on electric power, and low manufacturing costs. However, these motors have a number of disadvantages such as noise due to brush friction, generation of sparks and electrical noise, and limited life due to brush wear. Development of the brushless DC motor has solved all these problems.
We have several different style brushless motors
1, Y series frame brushless dc motor ofr industry machinery. The power from 0.55kw to 15kw. Frame size: 80, 90. 100. 112. 132
2, Circle Housing for Go Kart,Electric Scooter,Two Wheel Balance Scooter,E-Bike Electric Motorcycle,DIY Engine,Etc, 350W/500W/800W/1000W/1200W/1500W/1600W/1800W/2000W/2500W/3000W
Volt various from:24V/36V/48V
3. Custom some small size Brushless Motor. for general purpose, brushless motor for drone
Brushless Dc Motor,Motor Brushless,Dc Brushless Fan,Brushless Fan,24v DC Motor
Ningbo Biote Mechanical Electrical Co.,Ltd , https://www.biotept.com